Acres |
5.1 Acres |
| |
 |
Year Built |
1980, Renovated 1997 & 2005 |
| |
 |
Number of Floors |
Two |
| |
 |
Rentable Square Feet |
55,000 SF - Total
27,500 1st Floor / 27,500 SF 2nd Floor |
| |
 |
Parking Provisions |
4.0 surface parking spaces per 1,000 SF of leased area |
| |
 |
Building Amenities |
Convenient access to area hotels, restaurants, banks and retail as well as access to Routes 24,10 & 78, I-280 and I-287. |
| |
 |
Security System |
Card Access 24 hours per day, 7 days per week |
|
| |
 |
Structural Systems |
Structural Steel and metal deck |
| |
 |
Façade |
Masonry and Light gauge framing system with hard-coat EIFS system. Windows thermo break with insulated glass |
| |
 |
Floors |
Metal decking with Concrete Slab |
| |
 |
Roof |
4ply asphalt built-up with reflective coating |
| |
 |
Window Mullion Spacing |
5' |
| |
 |
Typical Column Space |
25' x 25' |
| |
 |
Max. Finished Ceiling Ht. |
8'6" |
| |
 |
Slab to Slab |
1st Floor - 11' 11"
2nd Floor - 12' 6" |
|
| |
 |
Number of Fire Stairs |
3 Stairwells |
|
| |
 |
Parking |
Handicap parking provided at each entrance |
| |
 |
Entry Doors/Ramps |
Entrances are in compliance |
| |
 |
Restrooms |
Restrooms are ADA accessible |
| |
 |
Elevators |
1 passenger (8 Person)- 2,500 lb capacity |
| |
 |
Fire Alarm System |
In compliance |
|
| |
 |
Cooling |
Cooling is accomplished by two, thirty-ton air-cooled self-contained Carrier roof top units (“RTU”) in the core areas. The perimeter of the building is serviced by through the wall incremental units (heat pumps). |
| |
 |
Heating |
Morning warm up through two thirty ton RTUs plus perimeter heat pumps |
| |
 |
Distribution |
Variable air volume system supplied by roof top air handling units with digital controls and automatic economizer cycles for efficiency |
| |
 |
Temp. Control Method |
Centralized Energy Management System |
| |
 |
Zones per Floor |
The zoning control is an average of one VAV box and thermostat per 1,200 SF. |
| |
 |
After Hours HVAC |
$75.00 per hour (4 hour minimum) |
| |
 |
Supplemental HVAC |
1 ½ ton package unit services Data room |
| |
 |
Wet Column Locations |
Interior columns |
|
| |
 |
Telecommunications |
Building has fiber optic access |
|
| |
 |
Sprinkler System Description |
Fully sprinklered |
| |
 |
Fire Alarm/Detection |
Electronic fire panel central station monitored |
|
| |
 |
Floor Load |
80 lbs. |